Who's Online
There currently are 5978 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
I purchased the unit from a private party and the original owners manual was not available. Having the ability to download it was extremely helpful and clarified operating the equipment immensely. This is a complicated unit and without the manual I would not have been able to maximize it's potential. Thank you.
;
Being a user of older radios of many kinds, preferring them over more modern rigs, this manual was invaluable in the programming of my two. I now know for certain what the assorted buttons functions are, and am very grateful to have found this excellent site. Many thanks for your assistance, Tony.
;
Clear and easy to read. All details as expected. Price acceptable , and quick delivery.
;
Quick response and exactly what I was looking for and at a great fair price!
;
5 star quality on these downloadable manuals. Easy to read and all the information is there. A must when doing a custom install or needing to service your precious old school electronics.
XC-E series
RESTART RESET (R.R)
The information on one screen can be extracted at any time by inputting a restart/reset signal (HD/VD) from the outside. To enter this mode, set DIP switches 6, 7, and 8 on the rear panel of a camera as shown in the table below. The setting is especially effective for the following operation.
Switch 1 2 3 4 5 6 7 8 9 0 Restart Reset (R.R) 0 0 0 0 0 1 1 1 0 0
1: ON 0: OFF
Long exposure
A high-sensitivity image is obtained by extending the exposure time of the CCD when satisfactory sensitivity cannot be obtained under other operating conditions or when observing the trail of a moving object. The exposure time is determined by the VD interval (T) period between external VD pulses as follows.
� Timing and conditions
Example 1 of Long exposure
EXT HD
Continuous signal: 15.734 kHz (XC-ES50/ES30, XC-EI50/XC-EI30)Allowable frequency value ±1%, 15.625 kHz (XC-ES50CE/ES30CE, XC-EI50CE/XC-EI30CE) Allowable frequency value ±1%
EXT VD
VD interval(T): 262.5H or more (XC-ES50/ES30, XC-EI50/XC-EI30) and less than 1 second (Recommended), 312.5H or more (XC-ES50CE/ES30CE, XC-EI50CE/XC-EI30CE) and less than 1 second (Recommended) Four or more VD pulses are required. T T T
Exposure time for Odd field Exposure time for Even field
Video output
Odd image Invalid image Even image Valid frame image
Odd and even fields are determined by the phase of the EXT HD/VD signal input from the outside.