Who's Online
There currently are 6043 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
This is a top quality manual. You couldn't get better if you had the original and scanned it yourself. Best price on the net as well. Diagrams are clear and complete, text is sharp and easy to read. Granted you don't get the manual the second you click pay, but the few hours you have to wait for it to be available for download isn't a problem at all. This is a very reliable company.
Very VERY pleased with the product, and will buy others. Thanks!
;
In a word AWESOME.
I never expected the quality and abundant content that I got with this manual. Everything you'd ever want to know from a service perspective is found in this manual, along with... as a bonus, operating instructions on how to use the unit. WOW. Very impressed with the quality of the manual. You won't be disappointed if you're looking for the EVS900 service manual.
;
I thank Owen-Manuals.com for the wonderful service rendered to me, and this manual which I purchased helped me a lot in servicing my Denon System, which was lying in a dead state.
Thanks Owner-Manual.com
;
I purchased this manual to repair my Teac set and with the support of this manual I rectified the problem.
Thanks Owner-Manuals.com
;
Excellent service manual, i didn't believe i could find it for such old product, it is very explanatory, managed to fix the disk player!!!
TUNER SECTION
0 dB=1 µV
FM VCO Adjustment Procedure :
FM RF signal generator 0.01µF
[AM] RADIO ON/BAND button : AM
AM RF signal generator
Put the lead-wire antenna close to the set.
to ANT (TP1) Carrier frequency : 98MHz Modulation : No moduration Output level : 0.1V (100dB)
30% amplitude modulation by 400Hz signal. Output level : as low as possible
1. 2. 3.
Connect the frequency counter to the positions shown below. Turn the set to 98 MHz. Adjust RV1 for 19,000 Hz reading on the frequency counter.
[FM] RADIO ON/BAND button : FM
FM RF signal generator 0.01µF to ANT (TP1)
Specification Value: Digital frequency counter 18,900 to 19,100 Hz
Frequency counter TP23 1µF
+ �
22.5kHz frequency deviation by 400Hz signal. Output level : as low as possible Level meter 16� set
+ � 2 REMOTE jack (J701)
(IC7 pin !�) 100� IC7 pin 9
Adjustment Location : [TUNER BOARD] � SIDE A �
� Repeat the procedures in each adjustment several times, and the frequency coverage and tracking adjustments should be finally done by the trimmer capacitors. AM TRACKING ADJUSTMENT Adjust for a maximum reading on level meter. L4 621kHz CT1 1,395kHz FM IF ADJUSTMENT Adjust for a maximum reading on level meter. L3 10.7MHz FM VOLTAGE ADJUSTMENT 1.05 to 1.15 V L2 76MHz
L2 : FM Voltage Adjustment L3 : FM IF Adjustment
TP1
CT1 : AM Tracking Adjustment
TP13 IC7 L4 : AM Tracking Adjustment
RV1 : FM VCO Adjustment
�8�
|
|
|
> |
|