|
Who's Online
There currently are 6043 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
It's a grate service manuals.Have many details and the writing it's so clear.You have all you want in manual,nothing missing,belive me.I'm verry satisfied of this manual.
;
Great scanned service manual
Usefull informations.
I will buy again!
Best Regards
;
The manual describes this product very good. It has the basic things to know and also a more detailed look. Very well made!
;
An excellent document to assist in the repair of my old personal tape player. It includes full circuit diagrams and physical layout drawings and full instructions on disassembly and fault finding.
Well worth the meagre price.
;
Very good conversation, Pretty fast Service, wood do it again,
Have paid by Paypal, so i got the Service Manual online after 15 Min.
Very helpfully.
Greeting from Germany,
Hans
Notes on Installation
Carry out the followings.
Maintenance
Maintenance
Note on the Time to Replace the Lamp
When it is time to replace the lamp, replace the lamp promptly with a new LMP-600 Projector Lamp.
For details on replacement, refer to the instruction manual supplied with the LMP-600 Projector Lamp.
Cleaning the Air Filter
The air filter should be cleaned every 300 hours. When it becomes difficult to remove the dust from the filter, replace the filter with a new one. To clean the air filter, follow the steps below:
No toppling of the unit
Avoid using as the unit topples over on its side. It may cause malfunction.
1 2
Turn off the power and unplug the power cord. Remove the air filter cover on the bottom of the projector.
Use to be level
Avoid using as the unit titles more than 20 degrees. Do not install the unit other than on the floor or ceiling. These installation may cause malfunction.
20°
20°
20°
3
20° 20°
Remove the air filter.
No blocking the ventilation holes
Avoid using something to cover over the front ventilation holes; otherwise, the internal heat may build up. Use the supplied front cover only when the power is turned off. Do not turn on the projector with the front cover on. It may cause malfunction.
4 5
Remove the dust from the filter with a vacuum cleaner. Attach the air filter and replace the cover.
Notes
� If the air filter is excessively dirty, wash it with a mild detergent solution and dry it in a shaded place. If the dust cannot be removed, replace the air filter with the supplied new one. � Be sure to attach the air filter cover firmly; the power will not be turned on if it is not closed securely.
36 (EN)
37 (EN)
1-19 VPL-S600
|
|
|
> |
|