Who's Online
There currently are 5857 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
This is the ONLY copy of this manual I could find for a realistic price. Even Panasonic could not provide me with one.
The PDF is a very good copy and it helped me diagnose and find the fault with the unit I have.
;
Very complete and well reading drawings. Documentation is essential for successful repairs.Good documentation, with all that is necessary. This manual was what I was waiting with all the information necessary for the repairing I need it for. You must buy it if you want to do repairs or simply understand how it works.
;
Excellent service manual includes everything is need to repair this radio-caseete, how to disassemble, wiring diagram, all , waiting time until the download was only a few hours. I'm going to buy service manuals from here, are cheap and very good.Thank you.
;
Good service manual,i saved from scrapping this deck,is now fully functional.Thanks.
;
Found this to be the manual included with the original packinging, was helpfull but did not give any detailed repair instructions.
Section 3 Self Diagnostics
3-1. Error Code and Self Diagnostic functions
When the trouble occurs while setting up the system, perform the following self diagnostics according to error code contents.
Error code [E1], [E2] Cause of error, Self diagnostic proceeding and confirming (1) Perform the remedy for �error indications�. (Refer to �Error Indications� on page 74 of Operating Instructions.) (2) If �error indications� is still remaining, perform and confirm the following either self diagnostic. . �Sec.3-2-4. Self diagnostic of the camera control block on the CPU-331 board� (page 3-4) (Perform the front panel buttons operation) . �Sec.3-2-3. Self diagnostic of the camera control block on the CPU-331 board� (page 3-3) (1) Perform the remedy for �error indications�. (Refer to �Error Indications� on page 74 of Operating Instructions.) (2) If �error indications� is still remaining, perform and confirm the following either self diagnostic. . �Sec.3-2-4. Self diagnostic of the camera control block on the CPU-331 board� (page 3-4) (Perform the front panel buttons operation) . �Sec.3-2-3. Self diagnostic of the camera control block on the CPU-331 board� (page 3-3) n Make sure bit switch of RS-232C portion that is installed in rear panel of the unit (SX-M10), is set correctly. (Refer to Operating Instructions on page 48.) When both CPUs on the CPU-331 board could not establish a communication, the error code [E5] will be indicated. (1) Perform and confirm the following self diagnostics. . �Sec.3-2-1. Self diagnostic of the SX block on the CPU-331 board� (page 3-2) . �Sec.3-2-4. Self diagnostic of the camera control block on the CPU-331 board that is performed the front panel buttons operation on the unit� (page 3-4), or �Sec.3-2-3. Self diagnostic of the camera control block on the CPU-331 board� (page 3-3) n When slide switch S3 is set to DIAG position or bit switch S2 is set to ON position on the CPU-331 board, the error code [E5] may be indicated. In this case, make sure confirm the both switches setting position. (Normally, slide switch S3 is set to NORMAL position and bit switch S2 all of eight bits are set to OFF positions.) When power of the unit (SX-M10) is turned on, the error code [__] remains indicating in case that the unit could not establish a communication to the videoconference system. (When a communication to the videoconference system is completed normally, the error indication goes off.) In this case, confirm the same remedy for error codes [E1] and [E2] as described in above. When microphone switches of the SX-C100A/D100A are set to ON, the microphone number is not indicated on the unit (SX-M10). (1) In that case, perform and confirm the following self diagnostics. . �Sec.3-2-1. Self diagnostic of the SX block on the CPU-331 board� (page 3-2) . �Sec.3-2-2. Self diagnostic of the D/C UNIT on the CPU-331 board (delegate�s and chairman's unit)� (page 3-3) n When slide switch S3 is set to DIAG position or bit switch S2 is set to ON position, the lamp of the SXC100A/D100A will blinking and microphone number may not be indicated. In this case, make sure confirm the both switches setting positions. (Normally, slide switch S3 is set to NORMAL position and bit switch S2 all of eight bits are set to OFF positions.)
[E3], [E4]
[E5]
[__] (However, in case of remains On the error code [__] after power of the unit (SX-M10) was turned on.) � (No error indication)
SX-M10
3-1
|
|
|
> |
|