Who's Online
There currently are 209 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
 |
|
There are currently no product reviews.
 ;
This is quiet a rare manual, I Have looked for this manual for quiet a while now, I have finally found it here. I believe this is the only place they have them in a very nice scan, Excellent guide: very clear, enabling us to print readable diagram overall it is great to have this manual available for purchase. This is a complete service manual no pages are missing. Thanks
 ;
This SM is quiet scarce and hard to find it is an excellent Service manual, very clear to read and to print schematics and diagrams, Hi quality, Complete manual with no pages missing. I am very pleased with the manual and the fast service I have received. Great place to shop.
Good luck finding you manual...
 ;
Quick delivery, the document was usefull, although the copy was i little bit unclear in the details.
 ;
A complete and well done copy of the manual, at a not expansive price!
The delivery of the manual is very fast.
Thank you for all
 ;
Perfect quality. Was able to fix speed drifting on my Sansui Turntable using the service manual instructions for PLL adjustment.
3-6. CONVERGENCE ADJUSTMENT
1. Input the dot pattern signal. Set CONTRAST to the position at which it can be seen clearly. Set BRIGHTNESS to MIN. 2. Align the R, G, B dots in the horizontal direction at the center of the screen using RV703 (H-STAT). Note: If H-CENT was changed after adjusting HSTAT, adjust H-STAT again. (The HSTAT can be changed by the H-CENT switch.) 3. Align the top and bottom of R, G, B at the center of the screen using the V-STAT (vertical static convergence) magnets. Note: After the V-STAT adjustment, always paint the magnets to lock.
I I' I I'
5. For VMC, use a 6-pole magnet to adjust so that the R and B dots are symmetrical above and below the G dot.
R (Top section) Fixed G B
(Bottom section)
6-pole magnet Perform the VMC adjustment by rotating the 6-pole magnet to the left and right without changing the opening of it.
Adjust so that the displacement of the dot is equal at the top and bottom.
A
B
A
B
6. Repeat steps 2 to 5 until the convergence becomes correct. Note: Adjusting the convergence may affect the landing. Therefore be sure to check the landing again after completing this adjustment. 7. After adjusting, paint each magnet to lock them.
14-inch
X
X
Y Good example
Y Bad example
V.STAT convergence magnet Purity BMC magnet
While maintaining the V-STAT magnet knobs A and B at the same angle (I = I'), adjust the top and bottom convergences. If A and B are asymmetrical (I = I'), it will have a negative effect; the focus may not be accurate, or the beam striking may occur. 4. For HMC, use a 6-pole magnet and adjust so that the R and B dots are symmetrical at the left and right sides in respect to the G dot.
I I' R G B
20-inch V.STAT convergence magnet
A
B A A'
Purity BMC magnet
6-pole magnet Perform the HMC adjustment by changing the opening of the 6-pole magnet.
Adjust the 6-pole magnet so that A = A'. While maintaining the I and I' angles equal, adjust the 6-pole magnet.
3-6