Manual is in German but complete. I needed this one to fix a long lasting problem with the internal PSU of the camera. Most of the capacitors begin to leak after a few years wich results in the inability to power on the camera. When you try to turn it on the power led flickers and the unit directly turns off. Thanks to this manual I was able to locate all bad cap's and to dis- and reassemble the camera without any problems.
We received the manual in a timely manner and it was exactly what we were expecting.
Text excerpt from page 14 (click to view)
HANDSET SECTION
MANUAL TEST MODE Set the Test Mode: 1. Enter the test mode by pressing key while pressing 1 and TALK keys when in idle condition. (Key operation n 1 n TALK ) 2. The RINGER will ring for 1 sec when the test mode is started. 3. Measurement mode of consumption current. (ch=01 state) 4. Use key input to carry out the various settings. 5. Use port inputs to set output from LED terminals. Release the Test Mode: 1. Press the OFF key. 2. Turn off the power. (Remove the battery and replace them.)
MACHINE TEST MODE Set the Test Mode: 1. When power on reset is applied while a �L� (low) is input the TEST I/O (TP316) terminal (IC401 #§ pin), the RING (Level H, 1 sec) sounds. 2. Checking the CH No. displayed on the LCD, up or down the JOG dial and select the No. It can be set by pushing the JOG dial. (�?� appears at the suffix No. is determined.) 3. Set the TX setting to TX OFF. 4. The channel is set by voice not by data. 5. Use port inputs to set output from LED terminals. Release the Test Mode: 1. Press the OFF key. 2. Remove the short plug and turn on the power.