Who's Online
There currently are 6043 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
Impressively thorough. Even the simple operators manual helped me "fix" one of the 2 CD players in the unit. This unit reads CD's from the top so they should be installed in the magazines "upside down" from typical CD players. The CD player service manual helped me unjam a stuck carriage because somebody transported the box laying down loaded with CD's. A little lens cleaning & the player now works well! Thanks for you help at a great price! Joe
;
I was skeptical at first but later found the manual to be good quality for the price. It took a couple hours to receive the email with the download link, well worth the wait. Thanks.
;
very helpful, I could not have cleaned motherboard and replaced the main fan without it
;
Good manual, schematics nice and clear with good quality scanning. Woul dhave been nice to have immediate access after purchasing though.
;
I was very glad recieving the service manal from You. Manuals were delivered promptly and were correct as advertised. A complete and very usefull service manual with all details. Thank you!
2-4-6. Playback Level Check (MA-286 Board) Mode Playback Signal Alignment Measurement point Measuring instrument Specified value Alignment tape : SP mode color bar portion Video LINE OUT terminal Oscilloscope A=1.00 ± 0.02Vp-p
2-5-1. ACE Head Adjustment Refer to the �VHS mechanical adjustment manual 11). 2-5-2. E-E Output Level Check Mode Signal Measurement point Measuring instrument Specified value
� (9-973-623-
E-E 400Hz, �7.5dBs : IC540 pin 5 (2) CJ540 L/R Audio level meter �7.5 ± 2dBs ( ) : R-ch
[Check Method] 1) Check that the playback level satisfies the specified value.
A
[Check Method] 1) Input signal of 400Hz and �7.5dBs to the CN540 pin 5 (2). 2) Check that the audio output level is �7.5 ± 3dBs. 2-5-3. Overall Output Level and Distortion Factor Check Mode Self-record playback Signal Measurement point Measuring instrument Specified value 400Hz, �7.5dBs : IC540 pin 5 (2) IC540 pin 3 (1) Audio level meter and Distortion meter Playback Level: �6.3 ± 3dBs Distortion: 4.0% or less ( ) : R-ch
H
Fig. 7-2-9. 2-4-7. VCO Frequency Adjustment (MA-286 Board) Mode Signal Measurement point Measuring instrument Adjustment element Specified value Playback Alignment tape : SP mode color bar portion IC500 pin @§ Digital voltmeter CT500 A=2.4 ± 2.5Vdc
[Check Method] 1) Adjust CT500 until DC output level at IC 500 pin @§ (F. C) satifies the specification.
A 0V 1H
[Check Method] 1) Input signal of 400Hz and �7.5dBs to the audio input. 2) Record signal. 3) Playback the recorded portion. 4) Check that the output level is �6.3 ± 3dBs. 5) Check that the distortion factor is 4.0% or less. 2-5-4. Overall Noise Level Check Mode Signal Measurement point Measuring instrument Specified value Self-record playback No signal (Insert a shorting plug into the Audio LINE IN terminal) IC540 pin 3 (1) Audio level meter (IHF-A weighing filter is used) � 45.5dBs or less ( ) : R-ch
Fig. 7-2-10 2-5. AUDIO SYSTEM ADJUSTMENT � For the adjustment of the audio system, perform in the SP mode if there is no special notes. Use the alignment tape. [Connecting Instruments]
(CN540) Audio line OUTPUT L/R (CN540) Audio line INPUT L/R Audio oscillator 600� Attenuator VTR 47k� Audio level meter or distortion meter
[Check Method] 1) Record. 2) Playback recorded portion. 3) Check that noise level is � 45.5dBs or less.
Fig. 7-2-10. � Adjust in the SP mode if there is no special indications. � Perform the adjustment setting the switch on the following positions. � CHANNEL switch .................................................. LINE 1 [Adjustment Method] 1. ACE head adjustment.....Refer to the VHS mechanical adjustment manual . 2. E-E output level check 3. Overall Output level and distortion factor check 4. Overall noise level check.