|
Who's Online
There currently are 5938 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
The service was quick and simple, finding the service manual easy and it appears to be the original with colour schematics. It contained the info I was after and so sorted the problem.
I have copied it to CD and attached the envelope to the inside back cover of the owners manual. Good manual and excelent service. Robin Wood, Wood Electronics, New Zealand.
;
Exactly what was needed to assess the product - excellent value and great service
;
Nice to have the service manual for the Sony DCR-TRV345E now. The document is of excellent quality.
;
MACKIE HR824 26 pages English-only Service Manual contains:
1) HR824 technical overview with the description of front and rear panel switches.
2) HR824 specs
3) Block Diagram
4) Wiring Diagram
5) Packaging management
6) Spare part & final assembly list (for PCB rev A and B) + exploded view
7) Test Procedures (where, how to measure voltage...) including Test Point diagram on the PCB.
8) IC and Transistor charts.
Excellent guide: very clear, good scan quality enabling us to print readable diagram :-)
Note:
Mackie HR824 make extensive use of surface mount devices (SMD). Service on the HR824 must
only be undertaken by experienced service technicians with the right tools, experience and patience to perform surface mount rework when needed.
;
This Service manual is very well scanned and its clean to read, no any anti-theft words that un-english could understand. I got my CCD600 working with this manual and it´s clear shematics :)
6-2-2(b) SKEW Adjustment Method Needed to minimize the variations in Skew of the Pickup unit and to provide optimum match with the recorded signal on the Disc. 1) Connect an Oscilloscope to the �SKEW� Test Point (See Fig. 6-5). 2) Connect Power, Open the Tray and Play the TDV-533 Disc, Chapter 14. � Set the Oscilloscope Range as follows : (Voltage ; 50mV/Div., Frequency ; 10m Sec.) 3) Adjust the Screws �A� and �B� (See Fig. 6-6) using a Hex screwdriver until you obtain a Flat Waveform and the picture is stable. Then, go to Chapter 1 and make sure the Waveform is Flat here as well. If not, you have to go back to Chapter 14 and adjust again. If you cannot obtain a Flat waveform, then the unit is defective. Note: The Deck must be in a horizontal position. Use both �A� and �B� screws to adjust.
Typical Waveform before Adjustment
Waveform after Correct Adjustment
Fig. 6-7 Envelope Waveform
6-6
|
|
|
> |
|