Who's Online
There currently are 5803 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
This is a great site. I placed my order and by the next am it was available for download. Had some problems with some missing copy on some pages. Once I brought the error to the OMC's attention, the issue was resolved. I'll come back again.
;
Mi spiace per non poter scrivere in inglese... ma sono veramente soddisfatto del servizio offerto. Grazie..!!
;
The quality of this manual is good. It has all schematics and setup information for both the MDS-B3 and the MDS-B4. The scan quality is quite good, all pages are readable, This service manual also contains scans of the operating instructions from the User manual.
;
Quick site processing. A complete and very useful manual with all details. Thank you!
;
Das Service Manual war von der ersten bis zur letzten Seite sehr informativ und hilfreich. Die Darstellung aller Teile war klar und der Text gut lesbar.
Vielen Dank, das war nicht der letzte Download bei ownner-manuals.com.
SCD-XA333ES
4-5 . AGING MODE (� Perform as necessary) 4-5-1. The aging can be performed to the set in the test mode The aging can be continued by the set number of times or until an error occurs. In the aging, the following operations are repeated. Table turntDisc chuckingtDisc detecttServo ontAuto adjustmenttTOC readingtPlay of first track for 5 secondtPlay of last track for 5 secondtPlay of first track for 5 secondtDisc unchucking Setting Method: 1. After setting the test mode, rotate the [l AMS L] dial to select �94. SET AGING� and press the [l AMS L] dial to enter. 2. When �AGING TIMES� is displayed, rotate the [ lAMSL ] dial to set the number of aging times. (For the number of times, every 10 times can be set. Setting 0 (zero) eliminates the count limitation where the aging is repeated until an error occurs)
Note: Do not perform unmanned overnight aging..
4-6. SHIPPING MODE The repaired set must be initialized, and for this purpose the set should be set to the shipping mode. Setting Method: 1. After setting the test mode, rotate the [l AMS L] dial to select �8d Set Up Init� and press the [l AMS L dial to ] enter. 2. �8D 000000000 00� will be displayed, and if the scroll starts in the left direction, the set initialization has completed 3. Press the [POWER] button to turn the power off.
Note: Take care not to leave the test disc in the set.
The following setups are established in the SHIPPING MODE Initialization of EEPROM (IC903) � PLAY MODE CONTINUE � M/2CH SELECT MULTI � DIGITAL FILTER STD � 2ch SPK MODE 2ch DIRECT � Mch SPK MODE Mch DIRECT � Resetting the accumulated hours meter.
3. Press the [l AMS L] dial, and �AGING START� will be displayed instantaneously, then �DISC IN & JOG ON� will be displayed and the tray will come out automatically. 4. Place a disc (CD or the SACD SL disc) on the tray. In the case of this set, the multiple discs can be placed. Even when the discs (CD or the SACD SL disc) of different types are mixed, the aging test can be performed. Use the [MULTI/2CH] key when placing a disc. When discs are placed in positions, press the [l AMS L] dial. 5. The aging test starts. 6. At the completion of aging by the set number of times, the tray will come out automatically and the check will stop. Typical time required for aging About 1 hour/100 times �AGING SUCCESS!� will be displayed if no error occurred in the aging, or the error will be displayed if an error occurred. (Refer to the following error list)
Error List An error occurring during the check in the aging mode of the test mode is displayed automatically (scroll display) immediately when the error occurred. < How to view the error history > 1. Select �95 DISP ERROR� with the [l AMS L] key, and press the [l AMS L] key once. 2. The error that has occurred lastly in the set and the signal status (H = 1, L = 0) at that time are displayed on the FL display by scrolling. (Types of the errors and the signal status that can be checked, are the same as the error display of the aging mode.) 3. Press the [l AMS L] key once again to show the error history repeatedly. 4. When the error history is displayed with scrolling once, the mode returns to the normal test mode.