|
Who's Online
There currently are 6025 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
It's a good manual, this one it's a scan from the original factory service manual, great quality 100% readeable. definetely it worths what I paid for.
;
A good manual! fast service and good qualityi for pdf document.
thanks!
;
Very helpful and complete manual. Maybe only one negative is schematics have sometimes unreadable name of the parts. But it's not a big problem.
;
Excellent high quality schematics brought my old Heidelberg back to life. Fast download at a reasonable price. Thanks.
;
This document is just what I was looking for, it´s very useful, it contains adjustment procedures for the final stage of the power amp and also
has a complete wiring diagram and description of the main semiconductors used in the design.
Set Check
92. SET CHECK SET TEST START 10. TOTAL CHECK 120. MANUAL CHK 121. LOAD IN ? (Not used.) 122. SPIN UP ?
0. IC&FL CHECK ?
11. AUTO CHECK ?
1. TOTAL CHECK ?
12. MANUAL CHK ?
2. F.JUMP CHECK ?
13. DISP RSLT ?
123. PARAMETER ?
3.HYB CHECK ?
TOTAL CHK END ?
124. READ TOC&PSP ?
4. DISP ERROR ?
125. 1/3 SEEK ?
END ??
126. 1-M SEEK ?
127. ERROR RATE ?
128. HENSHIN ?
129. SPIN DOWN ? 12A. LOAD OUT ? (Not used.) MAN. CHK END?
Press the [lAMS L dial when No.sssss sssss*1 is displayed, and a checking for that display will start or the lower layer ] will be selected. For the selection on the same layer, rotate the [l AMS L dial. It is looped on the same layer, and when �END?� is ] displayed, press the [l AMS L dial to return to the upper layer. ] *1 s denotes a displayed character. Manual Check Method In the �12. MANUAL CHK�, individual checks (121. LOAD IN to 12A. LOAD OUT) are possible.
Example: If 124. READ TOC of 12. MANUAL CHECK is to be checked.
Setting Method: 1. After setting the test mode, rotate the [l AMS L] dial to select �92. SET CHECK� and press the [ l AMS L] dial to enter. 2. When �SET TEST START� is displayed, rotate the [l AMS L] dial clockwise by 2 clicks to select �1. TOTAL CHECK?� and press the [l AMS L] dial to enter. 3. When �10. TOTAL CHECK� is displayed, rotate the [ l AMS L] dial clockwise by 2 clicks to select �12. MANUAL CHK?" and press the [l AMS L] dial to enter. 4. When �120. MANUAL CHK� is displayed, rotate the [ l AMS L] dial clockwise by 4 clicks to select �124. READ TOC&PSP?� and press the [l AMS L] dial to enter. 5. A checking will start automatically.
Note: In making a check, the disc must be loaded. Immediately when a check started, the tray is drawn into the set. Also, the tray can be opened/closed even during the set check mode.
57
|
|
|
> |
|