Who's Online
There currently are 6040 guests and 3 members online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
Veramente completo, dettagliato e perfetto nella visione. Perfect, thanks!
;
Fully functional usable service manual. Considering the age of the manual and device quality was better than expected
;
Thank you very much, I've been very happy to find this manual on "Owner Manual". It's a perfect copy and it has been really useful for my work!
;
It took about 24-hours after my payment before I was able to get to the download. Apparently, payment processing is not 100% automated. That is no big deal, just be aware of that going in.
After I got to it, it was in good shape, easy to read, etc. Not some cheap FAX copy looking thing.
Also, this site was the cheapest I found. Another Plus!
;
Good price, very legible manual, exactly what I needed -- but had to wait a day to actually get the download of the manual. Would have preferred to download it immediately after payment rather than waiting for someone to "process" my order. I was surprised that I had to wait that long.
The following is a simple adjustment method. � Simple Adjustment �
Note: Since exact adjustment cannot be performed, remember the positions of the controls before performing the adjustment. If the positions after the primary adjustment are only a little different, return the controls to the original position.
8. Connect the oscilloscope to TP (TRACKING-Y) and TP (VC) on the CD board. 9. Adjust RV704 so that the waveform is as shown in the figure below. (tracking gain adjustment)
VOLT/DIV: 1 V TIME/DIV:2 ms 0V
oscillosope (DC range) CD board TP (FOCUS-Y) TP (TRACKING-Y) TP (VC)
+ �
� Incorrect Examples (fundamental wave appears)
low tracking gain VOLT/DIV: 1 V TIME/DIV: 2ms 0V
Procedure: 1. Keep the set horizontal. If the set is not horizontal, this adjustment cannot be performed 2. 3. 4. 5. due to the gravity against the 2-axis device. Connect the oscilloscope TP (FOCUS-Y) and TP (VC) on the CD board. Insert the disc (YEDS-18) in and close the lid for CD. Put the set into test mode. (See page 30.) Press the ( button. From focus searching, focus is turned ON while entering CLV drawing-in mode. Tracking and sled are turned OFF. 6. Press the ( button. [Both tracking and sled are turned ON.] 7. Adjust RV702 so that the waveform is as shown in the figure below. (Focus gain adjustment)
VOLT/DIV: 100 mV TIME/DIV:2ms 100 mV 0V
high tracking gain high fandamental wave than for low gain VOLT/DIV: 1 V TIME/DIV: 2ms
0V
Note: VOLT/DIV: with the 10:1 probe in used.
10. Release test mode after adjustment is completed. � Inconnect Examples (DC level changes more than on adjusted waveform)
low focus gain VOLT/DIV: 100 mV TIME/DIV:2ms 250 mV 0V
Adjustment Location: CD board (See page 33.)
high focus gain VOLT/DIV: 100 mV TIME/DIV:2ms 100 mV 75 mV 0V
� 32 �