Description of SONY PFM510A2WE Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagrams, printed circuit boards, repair tips, wiring diagrams, block diagrams and parts list. Service Manual ( sometimes called Repair Manual ) is used mainly by technicians.

If You just want to know how to use Your tv, video, mp3 player etc. You should look for Owner's Manual. After placing order we'll send You download instructions on Your email address.

The manual is available in languages: English

Not yet ready
You must purchase it first

Customer Reviews
There are currently no product reviews.
Other Reviews
 BVU800P SONY Service Manual by John Thompson;
This is a good quality scan of the Operation & Maintenance (Service) Manual for the PAL version of this high-band broadcast umatic, BVU-800P All schematics and lineup procedures appear to be included in this one manual AFAICT. The file size is just over 113 MB which gives an idea of the quality and number of pages. All of the schematics, which contain some fairly small print, are easily readable when you zoom into the page. John Thompson, Newcastle Upon Tyne, England.
 CQ-984EG PANASONIC Service Manual by Adam Morawski;
Good quality, all schematics of few of models. There is also short form of user manual and regulation manual.
 DPSG7 KENWOOD Service Manual by Hanns Aschenneller;
Perfect copy of the service manual. you can enlarge every page, and it comes up with all details.
 BVW-300 SONY Service Manual by Marwey Butch;
It´s very very nice manual with all, what i need. Original in good quality. Very fast business. Very much thanks...
 DVL-90 PIONEER Service Manual by Fernando Rongvaux;
Purchased the manual that I was looking for at a great price and could download it easily.. Great service experience and for future purchases I plan to use the site. Thank you very much

Text excerpt from page 62 (click to view)
(13)INTERLACE MODE Whether the input signal is interlaced or not is set. ON : When the input signal is the interlaced signal. OFF : When the input signal is not the interlaced signal. (14)FIELD MODE Whether the interlaced signal is processed within a field or within a frame, is set. ON : When the input interlaced signal is processed within a field. OFF : When the interlaced signal is processed within a frame. Select the ON position when a signal has a low corelationship between the two fields within a frame such as moving picture. (15)FRAMELOCK MODE Whether the PDP display picture is synchronized with the input signal to scan converter or not, is set. ON : The PDP display picture is synchronized with the input signal. OFF : The PDP display picture is asynchronous with the input signal. When moving picture (animation) is going be displayed, select the ON position.
Note : This item can be set to ON as long as the vertical frequency of the input signal is in the range of 50 to 60 Hz.

(20)APERTURE INIT The desired aperture is selected from HIGH or MID or LOW. Result of this setting becomes the initial value of the user menu APERTURE. (21)APERTURE HIGH The scaling filter value when selecting HIGH of the APERTURE, is set. The scaling filter value can be set in the range of 000 to 011. (Refer to the Supplement to APERTURE in the following paragraph.) (22)APERTURE MID The scaling filter value when selecting MID of the APERTURE, is set. The scaling filter value can be set in the range of 000 to 011. (Refer to the Supplement to APERTURE in the following paragraph.) (23)APERTURE LOW The scaling filter value when selecting LOW of the APERTURE, is set. The scaling filter value can be set in the range of 000 to 011. (Refer to the Supplement to APERTURE in the following paragraph.) < Supplement to APERTURE > The PFM-500A3W/510A2W has the 12 different types of built-in scaling filter. Select an appropriate filter using the following filter characteristics chart as a guideline.

(16)MATRIX SELECT The color difference matrix when the YUV signal is being input, is set. (17)PICTURE AGC Whether the PICTURE AGC is turned ON or OFF is set. Result of this setting becomes the initial value of the user menu PICTURE AGC. This function becomes valid only when the COMPOSITE/YC/YUV signal is being received. (18)ASPECT The desired aspect ratio is selected from the aspect ratios of 4 x 3 or 16 x 9 or W ZOOM. Result of this setting becomes the initial value of the user menu ASPECT.
Note : The W ZOOM can not be selected when the ZOOM is in the range of x 2 to x 4.

Wide (Sharp)

Frequency bandwidth

Narrow (Soft) 0 1 2 3 4 5 6 7 8 9 10 11

(19)ZOOM The desired zoom ratio is selected from the zoom ratios of x 1 or x 2 or x 3 or x 4. Result of this setting becomes the initial value of the user menu ZOOM.
Note : Any zoom ratios other than x 1 cannot be selected when the ASPECT is W ZOOM.