Who's Online
There currently are 5583 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
Original well scanned manual. Got the job done. Microwave problem found & corrected. For $5 and a new magnitron from ebay, it was a cheap and good the first shot fix. Electrical schematics allowed me to mage sure every thing else was ok before cutting and order for parts. Hard to live without.
;
I was very skeptical of this website, I have never downloaded manuals before. I put it on the AMEX and payed through Paypal to ensure protection. I got the manual exactly as described and now I can replace the filter capacitor for this amp. Great Price, others selling for 12.99 or more and this is the same manual. I will search out this website for other manuals. Thank you
;
Manual was reasonably easy to follow. I am not an engineer or know much about electronics but with the manuals help I was able to figure out the problem, identify the part required for the repair. Replacement part cost around $30. Whilst replacing the part I was telling myself, "this aint gonna work cos it seems far too easy". Took about 15 minutes to do and my plasma TV works a treat. Would never have been able to do this without the service manual.
;
It is OK, this manual help me to repair my dynacord
;
Good manual. Even it is an old printed manual, it is well scanned and complete, with all drawings, schematics and parts list. Very good return for the cost.
4-1. Check Items Before Starting Self-diagnostics
3. When the DE-55 board is suspected to be defective . Select an oscilloscope setup of 20 MHz with band-width limit: OFF. . Adjust the brightness of the incoming light until 400 mVp-p is obtained at TP401 and TP402. . The circuit stage up to TP141 must be diagnosed by observing the waveform of the carrier signal and by checking the operating condition with no input signal fed to the infrared transmitter. The circuit stages after that must be diagnosed by observing the demodulated waveform and by checking the operating condition with the color bar signal being input to the infrared transmitter. a) Check that the DC voltages that are supplied from the power supply to the respective blocks are correct or not. � When the DC voltages are normal, the voltages from MA-107/107P board are; TP491: 5 ± 0.5 V, TP391: 9 ± 0.5 V. � When DC voltages are abnormal; Soldering of CN101 is suspected to be defective, or flexible flat cable (FFC) has poor connection or is broken. b) Check DC voltage at L491 and check the signal flow from TP401 to TP404. [RF amplifier] � When the circuit is normal, the waveforms [No. 1 to No. 5] that are shown on page 4-21 can be obtained with no input signal fed to the infrared transmitter. � When the circuit is found abnormal; Resoldering the poorly soldered joint in the circuit block of Ref. 400 to Ref. 409. Replace the transistor as needed. c) Check DC voltage at L492 and check the signal flow from TP421 to TP424. [RF amplifier] � When the circuit is normal, the waveforms [No. 1 to No. 5] that are shown on page 4-21 can be obtained with no input signal fed to the infrared transmitter. � When the circuit is found abnormal; in the circuit block of Ref. 420 to Ref. 439. Replace the transistor as needed. d) Check DC voltage at L491. [ANALOG_5.9 V] � When the circuit is normal; 5.9 ± 0.5 V � When the circuit is found abnormal; Resoldering the poorly soldered joint in the circuit block in which abnormality has occurred. Replace the transistor Q901 or others as needed. e) Check Q110 for correct operation by observing the output waveform at TP101. [BUFFER] � When the circuit is normal, the waveform [No. 6] that is shown on page 4-21 can be obtained with no input signal fed to the infrared transmitter. � When the circuit is found abnormal; Resoldering the poorly soldered joint in the circuit block in which abnormality has occurred. Replace the transistor Q110 or others as needed. f) Check IC101 for correct operation by observing the output waveform at TP102. [LIMITTER] � When the circuit is normal, the waveform [No. 7] that is shown on page 4-22 can be obtained with no input signal fed to the infrared transmitter. � When the circuit is found abnormal; Resoldering the poorly soldered joint in the circuit block in which abnormality has occurred. Replace IC101 or others as needed.
4-18
PCS-1600/1600P
|
|
|
> |
|