A site where discontinualed schematic diagrams and back dated information can be found on discontinued radios tv's and any electronic equipment can be found. Newer manuals either Service and operating manuals. Radio amateurs should find this site a great source for ham radio equipment manuals. I will return to this site should I need information on any electrical equipment. priced easy to download in a PDF format and print pages need to undertake the repair.
Text excerpt from page 16 (click to view)
1-7. OHB Fixing Tool
1-7. OHB Fixing Tool
OHB fixing tool (Sony P/N J-6395-100-A) is separately available to adjust the PA board of the OHB for a portable camera. How to Use 1. Install a tripod adaptor VCT-14 on the OHB fixing tool with the two screws, using the supplied allen wrench (width across flats: 3/16). n Tighten in order of 1 to 2 .
4. Secure the OHB to the OHB fixing tool with the four screws.
VCT-14
5. Attach the camera to the tripod adaptor. 6. Connect the cables to the OHB referring to the operation manual. n The tripod adaptor can slide to and fro. Align to a proper position when connecting between the OHB and camera, or adjusting the PA board.
(VCT-14 bottom view)
m . The OHB fixing tool with the camera installed can be mounted on a tripod with an 1/4 -inch or 3/8-inch screw. . If removing the spacer shown in the figure, you can fix the tripod adaptor to the OHB fixing tool. In this case, the tripod adaptor can not slide.
2
1
2. Remove the right side panel of the camera. Loosen the four screws and pull out the OHB from the camera. Disconnect the three cables from the OHB. 3. Remove the DR cover. (Refer to Section 1-2.)
Spacer
1-8 (E)
OHB-400/500/500WS & PAL OHB-450/451/550/550WS & PAL