This is a very good quality print (scan) of the original SONY service manual. The original from Sony is on very thin paper. Nevertheless it is very clear and sharp and excellent readable. I'm very satisfied to have now this rare document. I've looking for it many years (infrequent). It contains very detailed circuit diagrams, exploded views, part lists, PCB view with good readable connection lines. Very recommended.
;
A complete manual with all the needed details of calibrations and service instructions about the radio receiver.
A big deal.
Many thanks !
;
Fast delivery and good quality copy. To be recommended
;
Excellent product, very clear print. Detailed circuit and assembly diagrams - this enabled me to repair my CD player with confidence. I highly recommend this site.
;
Fast access, 100% correct and complete service manual
[Charge Threshold Level Adjustment]
Mode Signal Measurement point Measuring equipment Adjustment page Adjustment address Specification value D 0E, 0F, 10, 11, 12 YYh = D8h ± 06h Power ON Any Displayed data on adj. remote commander
Connection: Referring to Fig. 2-2, connect the following equipment. (1) Connect the regulated power supply and a digital voltmeter to the battery terminal. (2) Connect the adjusting remote commander to the CN902 on YM-11 (G)/(H) board. Adjustment Procedure: (1) Adjust the output voltage of regulated power supply so that the battery terminal voltage is 7.2 Vdc. (2) Turn ON the POWER switch on the set. (3) Set data: 01 to page: 1, address: 00. (4) Set data: 01 to page: 2, address: 00. (5) Set data: 01 to page: 2, address: 2C. (6) Adjust the output voltage of regulated power supply so that the battery terminal voltage is 8.3 ± 0.02 Vdc. (7) Read data (YYh) on page: 2, address: 2D. (8) Confirm that the data (YYh) satisfies the specification value. (9) Using the following formulas (calculation of hexadecimal numbers), calculate the adjustment data and enter them to respective adjustment addresses. Address: 0E D0E = YYh + 04h Address: 0F D0F = YYh Address: 10 D10 = YYh � 5Ah Address: 11 D11 = YYh � 55h Address: 12 D12 = YYh + 09h
Note: After setting each data, be sure to press the PAUSE button on the adjusting remote commander.
(10) Set data: 00 to page: 1, address: 00. (11) Set data: 00 to page: 2, address: 00. (12) Set data: 00 to page: 2, address: 2C.
Regulated Power Supply AF OSC
Attenuator
600 �
L
Digital Voltmeter Adjusting Remote Commander CN902 J101 A/V IN YM-11 (G)/(H) Extension Cable (J-6082-291-A) Pattern Generator
R
Video Output (75 �)
Fig. 2-2
2-8 E
|
|
|
> |
|