Who's Online
There currently are 5762 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
This site is working fine! Did buy a manual for SX-EX25L and after a while I could download it and fix the problem. Nice and easy!
;
Complete manual as pdf-file in very good quality. Very helpful and fast availability.
;
Complete service manual in very good scanning quality with all schematic and PWB graphics as well as assembly & maintenance instructions. A slight drawback is that the rastering of the PWB graphics sometimes makes it a bit difficult to follow fine traces, but no showstopper.
;
Purchased the manual that I was looking for at a great price and could download it easily.. Great service experience and for future purchases I plan to use the site. Thank you very much
;
Service manual in good quality, it was very helpful to me. Perfect service, I am very satisfied.
Jochen Kelm
2-2-4. Video input adjustment
1. Input All white 90 IRE signal of NTSC to the video input terminal. 2. Select Video Calibration from the AD Converter menu. 3. Adjust the Sub Contrast (Video) and then, adjust the detection values of G to the set value. Detection set value: 230 ± 3 4. Set the video input signal to All gray 20 IRE signal of NTSC. 5. Adjust the Sub Bright (Video) and then, adjust the detection values of G to the set value. Detection set value: 51 ± 3 6. Adjust the CB Offset (Video) and then, adjust so that the detection value of B is the same as G value. 7. Adjust the CR Offset (Video) and then, adjust so that the detection value of R is the same as G value. 8. Repeat step 5 to 7 until the detection set value in step 5 above is obtained. 9. Repeat step 3 to 8 until the detection set value in step 3 and 5 above are obtained.
2-2-5. Video coder input adjustment
1. Input All white 30 IRE signal of SECAM to the video input terminal. 2. Select By Adj from the Chroma decoder menu. 3. Adjust the By Adj (SECAM) and then, adjust so that the detection value of B is the same as G value. 4. Select Ry Adj from the Chroma decoder menu. 5. Adjust the Ry Adj (SECAM) and then, adjust so that the detection value of R is the same as G value. 6. Repeat step 3 to 5 until the detection values of R, G, and B reach the allowable error range. Allowable error ± 5 7. Set [Cal Mode] to [OFF] after the A/D calibration adjustment is completed.