KV-ES38M31/ES38M61/ES38M90/ES38M91
RM-916
4 BMC (Hexapole) Magnet.
If the red, green and blue dots are not balanced or aligned, then use the BMC magnet to adjust in the manner described below.
RG B R G B R GB
(2) Dynamic Convergence Adjustment Preparation: � Before starting this adjustment, adjust the horizontal static � convergence and the vertical static convergence Set the PICTURE and BRIGHTNESS to normal.
1. Adjust TLH. (TLH correction piece) 1 Receive the dot/hatch pattern signal and adjust picture quality by the menu. 2 Correct horizontal mis-convergence of red and blue of both sides on the X axis. When red is outside insert BMC magnet to right side (THL+)
R G B R G B
R G
B
views from DY neck. And when blue is outside, insert it to left side (THL�) and take both sides.
RB (B) (R) B R TLH + (R) (B) TLH -
5 Y separation axis correction magnet adjustment.
1. Receive the cross-hatch signal and adjust [PICTURE] to [MIN] and [BRIGHTNESS] to [STANDARD] . 2. Adjust the Y separation axis correction magnet on the neck assembly so that the horizontal lines at the top and bottom of the screen are straight.
Blue Red
2. Adjust V-TILT-TLV. Correct the vertical mis-convergence of red and blue of vertically sides on the Y axis. 3. Adjust YCH. Adjust horizontal mis-convergence of red and blue of vertically sides on the Y axis. Mentioned above steps 2 to 4 are adjusting respectively perform minuteness tracking.
Neck assy
Neck assy
YCH H-TRP
Red Blue
TLV
VM board VM board
BMC magnet
C board
RV9001
Note 1. The Red and Blue magnets should be equally far from the horizontal center line. 2. Do not separate the Red and Blue magnets too far. (Less than 8 mm)
VM board