Shopping cart is empty
 
English Polski Spanish 
Search For a Manual
 

(e.g. AA-V20EG JVC, ZX-7 Sony )
PayPal 1000+ rating Secure, Encrypted Checkout.
 
Who's Online
There currently are 310 guests and 
1 member online.
Categories
Information
Featured Product
Home >> SONY >> KV32HS20 Service Manual
 
 0 item(s) in your cart 

SONY KV32HS20
Service Manual


Tweet about this product and get $1.00 of store credit for instant use!
  • Contains Circuit Diagrams
  • Download
  • PDF Format
  • Complete manual
  • Language: English
Price: $4.99

Description of SONY KV32HS20 Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagrams, printed circuit boards, repair tips, wiring diagrams, block diagrams and parts list. Service Manual ( sometimes called Repair Manual ) is used mainly by technicians.

If You just want to know how to use Your tv, video, mp3 player etc. You should look for Owner's Manual. After placing order we'll send You download instructions on Your email address.

The manual is available in languages: English

Not yet ready
You must purchase it first

Customer Reviews
There are currently no product reviews.
Other Reviews
 DMS500 KENWOOD Service Manual by Svend Kristensen;
very good quality that can be magnified several times, and it remains readable. For sure I will return next time the need for a service manual arise.
 SLHD501 PANASONIC Service Manual by Lorenzo Moreno;
The service manual is really great - thanks to it I was able to install the laser unit and thus "save" my CD-player, which seemed to be impossible before I had the manual.
 SX-PR307 TECHNICS Service Manual by Alexander McLeay;
Downloaded the Service manual OK of the Technics Piano and have now repaired it and its going fine. Excellant; thank you for the fine servce. A.M
 SX-EX25L TECHNICS Service Manual by Odd Pettersen;
This site is working fine! Did buy a manual for SX-EX25L and after a while I could download it and fix the problem. Nice and easy!
 B25EMOTION REVOX Service Manual by Georg Schuppien;
Complete manual as pdf-file in very good quality. Very helpful and fast availability.

Text excerpt from page 5 (click to view)
KV-32HS20/36HS20/36HS20H/32XBR450/36XBR450/36XBR450H

SAFETY CHECK-OUT
After correcting the original service problem, perform the following safety checks before releasing the set to the customer: 1. Check the area of your repair for unsoldered or poorly soldered connections. Check the entire board surface for solder splashes and bridges. 2. Check the interboard wiring to ensure that no wires are âpinchedâ or touching high-wattage resistors. 3. Check that all control knobs, shields, covers, ground straps, and mounting hardware have been replaced. Be absolutely certain that you have replaced all the insulators. 4. Look for unauthorized replacement parts, particularly transistors, that were installed during a previous repair. Point them out to the customer and recommend their replacement. 5. Look for parts which, though functioning, show obvious signs of deterioration. Point them out to the customer and recommend their replacement. 6. Check the line cords for cracks and abrasion. Recommend the replacement of any such line cord to the customer. 7. Check the B+ and HV to see if they are speciï¬ed values. Make sure your instruments are accurate; be suspicious of your HV meter if sets always have low HV. 8. Check the antenna terminals, metal trim, âmetallizedâ knobs, screws, and all other exposed metal parts for AC leakage. Check leakage as described below. 3. Measuring the voltage drop across a resistor by means of a VOM or battery-operated AC voltmeter. The âlimitâ indication is 0.75 V, so analog meters must have an accurate low voltage scale. The Simpsonâs 250 and Sanwa SH-63TRD are examples of passive VOMs that are suitable. Nearly all battery-operated digital multimeters that have a 2 VAC range are suitable (see Figure A). Leakage Test The AC leakage from any exposed metal part to earth ground and from all exposed metal parts to any exposed metal part having a return to chassis, must not exceed 0.5 mA (500 microamperes). Leakage current can be measured by any one of three methods. 1. A commercial leakage tester, such as the Simpson 229 or RCA WT-540A. Follow the manufacturersâ instructions to use these instructions. 2. A battery-operated AC milliammeter. The Data Precision 245 digital multimeter is suitable for this job.

How to Find a Good Earth Ground A cold-water pipe is a guaranteed earth ground; the cover-plate retaining screw on most AC outlet boxes is also at earth ground. If the retaining screw is to be used as your earth ground, verify that it is at ground by measuring the resistance between it and a cold-water pipe with an ohmmeter. The reading should be zero ohms. If a cold-water pipe is not accessible, connect a 60- to 100-watt troublelight (not a neon lamp) between the hot side of the receptacle and the retaining screw. Try both slots, if necessary, to locate the hot side on the line; the lamp should light at normal brilliance if the screw is at ground potential (see Figure B).

To Exposed Metal Parts on Set
Trouble Light AC Outlet Box Ohmmeter

0.15 µF

1.5 k

AC Voltmeter (0.75V)
Cold Water Pipe

Earth Ground

Figure A. Using an AC voltmeter to check AC leakage.

Figure B. Checking for earth ground.

â5â