Shopping cart is empty
 
English Polski Spanish 
Search For a Manual
 

(e.g. AA-V20EG JVC, ZX-7 Sony )
PayPal 1000+ rating Secure, Encrypted Checkout.
 
Who's Online
There currently are 6043 guests online.
Categories
Information
Featured Product
Home >> SONY >> KV-27S42 Owner's Manual
 
 0 item(s) in your cart 

SONY KV-27S42
Owner's Manual


Tweet about this product and get $1.00 of store credit for instant use!
  • Download
  • PDF Format
  • Complete manual
  • Language: English
Price: $4.99

Description of SONY KV-27S42 Owner's Manual

Complete owner's manual in digital format. The manual will be available for download as PDF file after You purchase it.

Owner's Manual ( sometimes referred to as User's Guide or User's Manual ) contains information on how to use Your device. After placing order we'll send You download instructions on Your email address.

The manual is available in languages: English

Not yet ready
You must purchase it first

Customer Reviews
There are currently no product reviews.
Other Reviews
 RX-505VLTN JVC Owner's Manual by John Heizer;
Absolutely perfect! I've been trying to understand how to use all or at least some of the features of the receiver and especially the remote.
 PM2521 PHILIPS Owner's Manual by David Jesson;
Copy of genuine owners/operators manual, very useful
 RDB365D CLARION Owner's Manual by Tina Whisnant;
The manual was a perfect match and was exactly what I was looking for. I'm very satisfied with my purchase.
 CXNA10 AIWA Owner's Manual by Roberta Barr;
Thank you for having the manual I needed for an older model Aiwa stero I had found on Ebay --- I wanted the Aiwa because I had tapes and cd's but I did not have a manual as to how to operate the system... I found what I needed and it has enabled me to set the system up for my enjoyment.
 S310 JBL Owner's Manual by Jos Vallen;
I wished detailed information of the JBL S310 and here I found it! Very happy with the service from this site!

Text excerpt from page 8 (click to view)
KV-27S42/27S46/27S66/29AL42/29AL42C/29AL66/ 29AL66C/29SL42/29SL42C/29SL46/29XL42M

SAFETY CHECK-OUT
After correcting the original service problem, perform the following safety checks before releasing the set to the customer: 1. Check the area of your repair for unsoldered or poorly soldered connections. Check the entire board surface for solder splashes and bridges. 2. Check the interboard wiring to ensure that no wires are �pinched� or touching high-wattage resistors. 3. Check that all control knobs, shields, covers, ground straps, and mounting hardware have been replaced. Be absolutely certain that you have replaced all the insulators. 4. Look for unauthorized replacement parts, particularly transistors, that were installed during a previous repair. Point them out to the customer and recommend their replacement. 5. Look for parts which, though functioning, show obvious signs of deterioration. Point them out to the customer and recommend their replacement. 6. Check the line cords for cracks and abrasion. Recommend the replacement of any such line cord to the customer. 7. Check the B+ and HV to see if they are specified values. Make sure your instruments are accurate; be suspicious of your HV meter if sets always have low HV. 8. Check the antenna terminals, metal trim, �metallized� knobs, screws, and all other exposed metal parts for AC leakage. Check leakage as described below. Leakage Test The AC leakage from any exposed metal part to earth ground and from all exposed metal parts to any exposed metal part having a return to chassis, must not exceed 0.5 mA (500 microampere). Leakage current can be measured by any one of three methods. 1. A commercial leakage tester, such as the Simpson 229 or RCA WT-540A. Follow the manufacturers' instructions to use these instructions. 2. A battery-operated AC milliammeter. The Data Precision 245 digital multimeter is suitable for this job. 3. Measuring the voltage drop across a resistor by means of a VOM or battery-operated AC voltmeter. The �limit� indication is 0.75 V, so analog meters must have an accurate low voltage scale. The Simpson�s 250 and Sanwa SH-63Trd are examples of passive VOMs that are suitable. Nearly all batteryoperated digital multimeters that have a 2 VAC range are suitable (see Figure A).

How to Find a Good Earth Ground A cold-water pipe is guaranteed earth ground; the coverplate retaining screw on most AC outlet boxes is also at earth ground. If the retaining screw is to be used as your earth ground, verify that it is at ground by measuring the resistance between it and a cold-water pipe with an ohmmeter. The reading should be zero ohms. If a coldwater pipe is not accessible, connect a 60- to 100-watt trouble light (not a neon lamp) between the hot side of the receptacle and the retaining screw. Try both slots, if necessary, to locate the hot side on the line; the lamp should light at normal brilliance if the screw is at ground potential (see Figure B).

Figure A. Using an AC voltmeter to check AC leakage.

Figure B. Checking for earth ground.

�7�

You might also want to buy

$4.99

KV27S42 SONY
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…
>
Parse Time: 0.173 - Number of Queries: 111 - Query Time: 0.047