Who's Online
There currently are 5862 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
Very fast and perfect delivery. Clear and well scanned. A lot of work professionally realized.
Again thak you a lot
;
This manual is accurate and of high quality. It is only volume 2 of the service manual. This is schematic, parts lists, and exploded mechanical drawings. The theory of operation and the diss-assembly instructions are in volume 1. The unit can be tricky to dis-assemble portions of so the volume 1 manual can be important. The product description of the manual is accurate but it does not say anything about volume 1 and the image of the front page does clearly say Volume 2.
;
Wellll again thank you very much fast and effective. Clear and well done for such an old TV!!!!
;
It has all the information you will need to fix it. The main circuit diagram is only A4 but being a PDF, you can print it to any size - I did it on two sheets of A3 and it didnt lose any detail - just made it readable when pinned up above the bench. I've found the fault, just need to buy some obscure bits to get it going again!
I cant fault the process, I paid for the manual in the morning and it was ready to download by lunch time.
;
Very good copy in a 54 pages PDF archive. This is my sixth purchase here. :)
KD-32FS130/36FS130
SECTION 2: SET-UP ADJUSTMENTS
The following adjustments should be made when a complete realignment is required or a new picture tube is installed. These adjustments should be performed with rated power supply voltage unless otherwise noted. Set the controls as follows unless otherwise noted: VIDEO MODE: Pro PICTURE CONTROL: Normal BRIGHTNESS CONTROL: Normal
Perform the adjustments in order as follows: 1. Beam Landing 2. Convergence 3. Focus 4. Screen (G2) 5. White Balance Note Test Equipment Required: 1. Color Bar Pattern Generator 2. Degausser 3. DC Power Supply 4. Digital Multimeter
2-1. BEAM LANDING
Before beginning adjustment procedure: 1. Feed in the white pattern signal.
6. Switch over the raster signal to red and blue and con�rm the condition. 7. When the position of the de�ection yoke is determined, tighten it with the de�ection yoke mounting screw. 8. If landing at the corner is not right, adjust by using the disk magnets.
Adjustment Procedure
1. Input a raster signal with the pattern generator. 2. Loosen the de�ection yoke mounting screw, and set the purity control to the center as shown below: Purity Control
Purity control corrects this area.
3. Turn the raster signal of the pattern generator to green. 4. Move the de�ection yoke backward, and adjust with the purity control so that green is in the center and red and blue are even on both sides.
Disk magnets or rotatable disk magnets correct these areas (a-d).
a c
b d
Deflection yoke positioning corrects these areas. b
Blue Red Green
d a c
5. Move the de�ection yoke forward, and adjust so that the entire screen becomes green.
KD-32FS130/36FS130