Original well scanned manual. Got the job done. Microwave problem found & corrected. For $5 and a new magnitron from ebay, it was a cheap and good the first shot fix. Electrical schematics allowed me to mage sure every thing else was ok before cutting and order for parts. Hard to live without.
;
I was very skeptical of this website, I have never downloaded manuals before. I put it on the AMEX and payed through Paypal to ensure protection. I got the manual exactly as described and now I can replace the filter capacitor for this amp. Great Price, others selling for 12.99 or more and this is the same manual. I will search out this website for other manuals. Thank you
;
Manual was reasonably easy to follow. I am not an engineer or know much about electronics but with the manuals help I was able to figure out the problem, identify the part required for the repair. Replacement part cost around $30. Whilst replacing the part I was telling myself, "this aint gonna work cos it seems far too easy". Took about 15 minutes to do and my plasma TV works a treat. Would never have been able to do this without the service manual.
;
It is OK, this manual help me to repair my dynacord
;
Good manual. Even it is an old printed manual, it is well scanned and complete, with all drawings, schematics and parts list. Very good return for the cost.
ICF-M410L SECTION 3 ELECTRICAL ADJUSTMENTS
MW/LW SECTION
BAND : AM � Repeat the procedures in each adjustment several times for the maximum level meter indication. � The frequency coverage and tracking adjustments should be finally done by the trimmer capacitors. AM IF ADJUSTMENT Adjust for a maximum reading on level meter. T15 450 kHz
AM RF signal generator Put the lead-wire antenna close to the set.
MW/LW FREQUENCY COVERAGE ADJUSTMENT
30% amplitude modulation by 400Hz signal. Output level : as low as possible
Adjust for a maximum reading on level meter. LW MW CT4 L4 153 kHz 531 kHz
FM SECTION
BAND : FM LW MW
MW/LW TRACKING ADJUSTMENT Adjust for a maximum reading on level meter. ANT102 CT2 ANT102 CT1 162 kHz 243 kHz 603 kHz 1,404 kHz
FM RF signal generator
0.01µF
telescopic antenna terminal
FM TRACKING ADJUSTMENT Adjust for a maximum reading on level meter. L6 87.5 MHz CT3 108 MHz
75kHz (100%) amplitude modulation by 1kHz signal. Output level : as low as possible
[Adjustment Location : Main board] (Component side)
level meter 16 � set + �
MAIN BOARD (Component side)
L6,CT3 T1 FM TRACKING AM IF adjustment adjustment
CT1 MW TRACKING adjustment
Speaker terminal (EPJ301)
L4 MW FREQUENCY CT2 COVERAGE LW TRACKING adjustment adjustment CT4 LW FREQUENCY COVERAGE adjustment