Very good service Within one day i received a pdf of the users manual and electric circuits so I was able to measure the different voltages in the printed circuit and find out the fault Payment was also reliable and easy.Without the manual i could not have repaired.So thanks to "Search for a manual"
;
you are doing great job guys.....my father ask me to find out the schematics of Sony KV25R1D to sort out the problem ..(he was electrical technician, and excperianced with TV and simillar stuff). finally he found the cause and change all necessary parts....now he has got working old dog..and is very happy!!... thank you all.. NB..he also saved the repair cost.
;
Perfect. Received my manual within 24 hours. Clear scan of the manual I needed. No problem.
;
Item as described, very well detailed manual with complete schematics. I've received the download information shortly after payment, very good support.
6-3. Self Diagnostics of BKDS-2010 Not Using Terminal
6-3. Self Diagnostics of BKDS-2010 Not Using Terminal
BKDS-2010 is able to check the following functions without using the terminal. Checks 1. SW SCAN TEST 2. 7SEG TEST 3. VOLUME TEST 4. LCD TEST 5. MEMORY TEST 1. SW SCAN TEST Procedure (1) Check that the AC inlet is disconnected from the rear panel of the BKDS-2010. (2) While pressing the [NORM] button on the control panel, connect the AC inlet to the rear panel to enter the SW SCAN TEST mode. For the details of this test, refer to the step (3) and later of �1. SW SCAN TEST� in �6-2-3. Self Diagnosis�. 2. 7SEG TEST Procedure (1) Check that the AC inlet is disconnected from the rear panel of the BKDS-2010. (2) While pressing the NORM button on the control panel, connect the AC inlet to the rear panel to enter REV the 7SEG TEST mode. For the details of this test, refer to the step (3) and later of �4. 7SEG TEST� in �6-2-3. Self Diagnosis�. 3. VOLUME TEST Procedure (1) Check that the AC inlet is disconnected from the rear panel of the BKDS-2010. (2) While pressing the [REV] button on the control panel, connect the AC inlet to the rear panel to enter the VOLUME TEST mode. For the details of this test, refer to the step (3) and later of �5. VOLUME TEST� in �6-2-3. Self Diagnosis�. 4. LCD TEST Procedure (1) Check that the AC inlet is disconnected from the rear panel of the BKDS-2010. (2) While pressing the [MULTI] button on the control panel, connect the AC inlet to the rear panel to enter the LCD TEST mode. For the details of this test, refer to the step (3) and later of �6. LCD TEST� in �6-2-3. Self Diagnosis�.
6-48
HDS-7150/7100
|
|
|
> |
|