Text excerpt from page 82 (click to view)
Error and Warning Messages
1 2
Press the DIAG button. The DIAG menu appears. Select ALARM, ERROR LOG, and then CANCEL EDIT.
CANCEL EDIT 1 LOST LOCK NO EXT REF V NO PB RF BATTERY NEAR BATTERY END TAPE NEAR CANCEL TOTAL:00
Item number currently being selected
Total number of items canceled
3
Press the UP button or DOWN/FREEZE button repeatedly to select the message to be canceled, and press the SET/FINE/SEARCH button.
CANCEL EDIT 4 LOST LOCK NO EXT REF V NO PB RF * BATTERY NEAR BATTERY END TAPE NEAR CANCEL TOTAL:01
An asterisk appears to the left of a canceled message. Canceled messages are no longer displayed or recorded in the error log. To display and save canceled error/warning messages in the error log again Do the procedure above to specify the messages to be displayed and saved in the log again, and then press the SET/FINE/SEARCH button.