Who's Online
There currently are 6030 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
I was having a hard time finding the problem with this Mackie 1604 unit. I didn't have a schematic. Went looking on the web and found your site and the price was more then reasonable. Ordered it and within the hour had the manual and within 15 minutes had the unit fixed. Best $4.99 I ever spent. Thank you.
Doug
;
This is a service manual in every sense of the word ( French and German versions of the text are included, as well as English..)
There are explanations of the mechanical and electrical functions, plenty of mechanical drawings, and the needed schematics. The quality of the scanning is excellent - all the component values are clearly legible - and very usefully there are pcb component layouts, so you can find a component on the schematic, and then very quicky pinpoint its physical location on the relevant pcb.
I cannot see how I can give this manual any less than the maximum 5 stars! Great value for money, which will pay for itself immediately. Excellent all round!
;
the manual is great and especially hard to find... thanks for the great service and having a hard to find manuel_
;
Please tell us what you think and share your opinions with others. Be sure to focus your comments on the product. You will receive $2.50 of store credit for Your review.
;
hat alles sehr gut geklappt. Das Servicemaual ist gut zu verwenden. Die Pläne und Schrift
ist klar und leserlich. Außerdem preiswert. Grüße an alle Hifi-Bastler
CD SECTION
Note: 1. CD Block is basically designed to operate without adjustment. Therefore, check each item in order given. 2. Use YEDS-18 disc (3-702-101-01) unless otherwise indicated. 3. Use an oscilloscope with more than 10 M� impedance. 4. Clean the object lens by an applicator with neutral detergent when the signal level is low than specified value with the following checks.
E-F Balance (Traverse) check (Without remote commander)
oscilloscope BD board TP (TEO) TP (VC) + �
S Curve Check
oscilloscope BD board TP (FEO) TP (VC) + �
Procedure: 1. Connect oscilloscope to test point TP (TEO) on BD board. 2. Turned Power switch on. Press [FUNCTION] button to select CD. 3. Put disc (YEDS-18) in to play the number five track. 4. Press the p button, [ENTER/NEXT] button and ^ button simultaneously several times to fluorescent indicator tube display �SHUFFLE� is blink. (The sledding servo is turned OFF.) 5. Check the level B of the oscilloscope�s waveform and the A (DC voltage) of the center of the Traverse waveform. Confirm the following: A � 100 = less than ±7 (%) B
Traverse waveform Center of the waveform
Procedure: 1. Connect oscilloscope to test point TP (FEO). 2. Connect between test point TP (FOK) and GND by lead wire. 3. Turn Power switch on. 4. Put disc (YEDS-18) in and turned Power switch on again and actuate the focus search. (Actuate the focus search when disc table is moving in and out.) 5. Check the oscilloscope waveform (S-curve) is symmetrical between A and B. And confirm peak to peak level within 3±1 Vp-p.
S-curve waveform
symmetry
B 0V A (DC voltage) symmetry level: 500 ± 100 mVp-p
A within 3 ± 1 Vp-p B
6. After check, remove the lead wire connected in step 2.
Note: � Try to measure several times to make sure than the ratio of A : B or B : A is more than 10 : 7. � Take sweep time as long as possible and light up the brightness to obtain best waveform.
6. Press the p button, [ENTER/NEXT] button and ^ button simultaneously several times to fluorescent indicator tube display �SHUFFLE� is OFF. (The sleding servo is turned ON.) Confirm the C (DC voltage) is almost equal to the A (DC voltage) is step 5.
Traverse waveform
RF Level Check
BD board TP (RF) TP (VC)
oscilloscope
+ �
0V
C (DC voltage) Sled servo OFF Sled servo ON
Procedure: 1. Connect oscilloscope to test point TP (RF) on BD board. 2. Turned Power switch on. 3. Put disc (YEDS-18) in and playback. 4. Confirm that oscilloscope waveform is clear and check RF signal level is correct or not.
Note: Clear RF signal waveform means that the shape ��� can be clearly distinguished at the center of the waveform.
� FR signal
VOLT/DIV: 200 mV TIME/DIV: 500 ns
level: 1.3 ± 0.3 Vp-p
� 16 �
|
|
|
> |
|