Text excerpt from page 178 (click to view)
DCR-PC103E/PC104E/PC105/PC105E
Ver 1.1 2003. 06
4.
DISCHARGING OF THE FLASHLIGHT POWER SUPPLY CAPACITOR (DCR-PC105/PC105E)
The power supply capacitor (C6606) of the ST-084 board is charged up to the maximum 300V potential. There is a danger of electric shock by this high voltage when the capacitor is handled by hand. The electric shock is caused by the charged voltage which is kept without discharging when the main power of the unit is simply turned off. Therefore, the remaining voltage must be discharged as described below. 4-1. PREPARING THE SHORT JIG To preparing the short jig. a small clip is attached to each end of a resistor of 1k�/1W (1-215-869-119) Wrap insulating tape fully around the reads of the resistor to prevent electric shock.
1 k�/1 W
Wrap insulating tape.
4-2.
DISCHARGING THE CAPACITOR (DCR-PC105/PC105E) Discharging method (2): 1 Remove the power supply (Battery or AC power adaptor). 2 Refer to page 2-3 to remove the cabinet (front) section. 3 Refer to page 2-5 to release the cassette cover lock and remove the cabinet (R) section. 4 Short-circuit between the TP6600 of the ST-084 board and the GND (GND of the accessory shoe) with the short jig about 10 seconds.
Short jig ST-084 board TP6600 Accessory shoe GND
Discharging method (1): 1 Open the flash. 2 Remove the power supply (Battery or AC power adaptor). 3 Remove the ST cabinet (Upper). 4 Short-circuit between the Xenon tube anode and the GND (GND of the accessory shoe) with the short jig about 10 seconds.