Who's Online
There currently are 6043 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
Exactly as described, a Service Manual complete with the schematics and PCB layout delivered in a timely manner. Many thanks for the great service.
;
some of the writing is a bit blur but the part in the schmatic was great and i have fixed the machine thanks
;
Well.. I'd searched for this manual and although I found many copies online I was pleased to find your website with a well balanced pricing system and easy to search and follow links. That together with the very quick response time was just what I was looking for.. being a very impatient tech.. ;-) I had the service manual in front of me within a short time.
Bookmarked.. and you can bet I will always come here first for my service & user manuals..
best regards
Ed(Tony) Foley
G7WHK
;
I will definitely be back for more information when I need it.
;
The service manual when downloaded and printed out was clear and easy to read. I would have liked to have been able to enlarge some details, but this was not possible as the file permissions did not allow this. The service was very good. The time taken from placing my order to downloading the document was only a few minutes.
CFD-S26 SECTION 4 MECHANICAL ADJUSTMENTS
PRECAUTION
1. Clean the following parts with a denatured-alcohol-moistened swab : record/playback head pinch roller erase head rubber belts capstan idlers 2. Demagnetize the record/playback head with a head demagnetizer. (Do not bring the head magnetizer close to the erase head.) 3. Do not use a magnetized screwdriver for the adjustments. 4. The adjustments should be performed with the rated power supply voltage (9V) unless otherwise noted. Torque Measurement Mode FWD Torque meter CQ-102C Meter reading 2.95 � 6.86 mN � m (30 � 70 g � cm) (0.42 � 0.97 oz � inch) 0.15 � 0.53 mN � m (1.5 � 5.5 g � cm) (0.021 � 0.076 oz � inch) CQ-201B more than 5.88 mN � m (more than 60 g � cm) (more than 0.83 oz � inch) more than 5.88 mN � m (more than 60 g � cm) (more than 0.83 oz � inch) Tape Speed Adjustment Procedure: Mode: playback
test tape WS-48A (3 kHz, 0 dB) 32 � set i jack (J321) digital frequency counter
SECTION 5 ELECTRICAL ADJUSTMENTS
TAPE SECTION 0 dB = 0.775 V
� Standard Output Level Output terminal load impedance output signal level � Test Tape Type WS-48A Signal 3 kHz, 0 dB Used for tape speed adjustment HP OUT 32 � 0.25 V (�10 dB)
FWD Back Tension
CQ-102C
FF
REW
CQ-201B
Adjust so that the value on the digital frequency counter is 3,000 Hz. Tape Tension Measurement Mode FWD Tension meter CQ-403A Meter Reading more than 100 g (more than 3.53 oz) Specification Value: Digital frequency counter 2,940 to 3,060 Hz Adjust so that the frequency at the beginning and that at the end of tape winding are between 2,970 to 3,030 Hz. Adjustment Location:
Tape speed adjustment control inside motor