MECHANISM ADJUSTMENT MODE � This mode is used for mechanism adjustments. Refer to the section on Mechanism Adjustments. SHIPMENT MODE � This mode is used for setting the unit to the shipment state. Do not execute it without a proper reason as it erases the memory of the title memo recorded by the customer. Procedure: Set the [COMMAND MODE] switch to [CD1] and the [TIMER] switch to [OFF]. Next, with the power ON, while pressing the [GROUP 5] button and [     ] button, press the [+100] button. If · the switch state is normal, the model name will be displayed on the fluorescent indicator tube and the unit will set into the shipment mode. If the various switches are not set to their designated positions, error codes will be displayed on the fluorescent indicator tube. TITLE MEMO RECORDING CHECK MODE This mode is not required for servicing. Do not execute without a proper reason. If executed, the memory of the title memo recorded by the customer will be erased.