Shopping cart is empty
 
English Polski Spanish 
Search For a Manual
 

(e.g. AA-V20EG JVC, ZX-7 Sony )
PayPal 1000+ rating Secure, Encrypted Checkout.
 
Who's Online
There currently are 6043 guests online.
Categories
Information
Featured Product
Home >> SONY >> CCU-TX7P Service Manual
 
 0 item(s) in your cart 

SONY CCU-TX7P
Service Manual


Tweet about this product and get $1.00 of store credit for instant use!
  • Contains Circuit Diagrams
  • Download
  • PDF Format
  • Complete manual
  • Language: English
Price: $4.99

Description of SONY CCU-TX7P Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagrams, printed circuit boards, repair tips, wiring diagrams, block diagrams and parts list. Service Manual ( sometimes called Repair Manual ) is used mainly by technicians.

If You just want to know how to use Your tv, video, mp3 player etc. You should look for Owner's Manual. After placing order we'll send You download instructions on Your email address.

The manual is available in languages: English

Not yet ready
You must purchase it first

Customer Reviews
There are currently no product reviews.
Other Reviews
 HSJ09 AIWA Service Manual by Julian D Hartheimer;
I Have looked for this manual for quiet a while now, I have finally found it here. I believe this is the only place they have them in a very nice scan, pages are very clear to read, some of the pages are a bit tilted but overall it is great to have this manual available for purchase. Thanks
 HS-PX10 AIWA Service Manual by Julian D Hartheimer;
This is quiet a rare manual, I Have looked for this manual for quiet a while now, I have finally found it here. I believe this is the only place they have them in a very nice scan, Excellent guide: very clear, enabling us to print readable diagram overall it is great to have this manual available for purchase. This is a complete service manual no pages are missing. Thanks
 HS-J08 AIWA Service Manual by Julian D Hartheimer;
This SM is quiet scarce and hard to find it is an excellent Service manual, very clear to read and to print schematics and diagrams, Hi quality, Complete manual with no pages missing. I am very pleased with the manual and the fast service I have received. Great place to shop. Good luck finding you manual...
 A701R/R-G PIONEER Service Manual by John Tandskov;
Quick delivery, the document was usefull, although the copy was i little bit unclear in the details.
 250M MARANTZ Service Manual by Cristiano Castellano;
A complete and well done copy of the manual, at a not expansive price! The delivery of the manual is very fast. Thank you for all

Text excerpt from page 23 (click to view)
2-6. SWITCH FUNCTIONS ON BOARD
CT-181 board
E1001 TP2006 CT-181
R TALLY
CONTACT POWER

RET FREQ

CV1

R TALLY CONTACT POWER DC24V

S2011 TP1000 E12 S2013 E1000 TP1002
RF AGC DLY

� S2002 (PROMPT SELECT TX/RX) TX : When selecting the TX mode, the CCU modulates the VBS signal input to the PROMPT VIDEO IN connector on the CCU-TX7/TX7P, and modulated signal is sent to the CA-TX7/TX7P. RX : When selecting the RX mode, the CA modulates the VBS signal input to the PROMPT VIDEO IN connector on the CA-TX7/TX7P, and modulated signal is sent to the CCU-TX7/TX7P. Note : When using this switch, change as follows. � In case of using the TX mode (TX side) ; 1) Disconnect CN8 and connect CN3 and CN7 on the CT-181 board. 2) Set S1 and S6 switches to "PROMPTER" side on the YD-25 board of CA-TX7/TX7P. � In case of using the RX mode (RX side) ; 1) Disconnect CN7 and connect CN3 and CN8 on the CT-181 board. 2) Set S1 and S6 switches to "AUX" side on the YD-25 board of CA-TX7/TX7P. Factory setting : TX � S2011 (R TALLY POWER/CONTACT) � S2013 (R TALLY DC24 V/TTL) These switches are set according to the signal standard of the R TALLY signal input to the INTERCOM/TALLY/ PGM connnector on the CCU rear panel. For the relation between the signal and switch setting, refer to the table below. Factory setting : (S2011) POWER (S2013) DC 24 V � S2012 (G TALLY POWER/CONTACT) � S2014 (G TALLY DC 24 V/TTL) These switches are set according to the signal standard of the G TALLY signal input to the INTERCOM/TALLY/ PGM connector on the CCU rear panel. For the relation between the signal and switch setting, refer to the table below. Factory setting : (S2012) POWER (S2014) DC 24 V
Switch Contact S2011, S2012 S2013, S2014 Contact DC 24 V or TTL Signal input method Power (+24 V) TTL (+5 V) Power DC24 V Power TTL

DC24V TTL

LOCAL REMOTE

RV22

G TALLY
CONTACT POWER

TTL R TALLY CONTACT G TALLY POWER DC24V G TALLY TTL MIC 1 GAIN

PROMPT FREQ

S2012 RV23 S2014
PROMPT LEVEL PROMPT TUNE

DC24V TTL

MIC GAIN
NORM MIN MAX

TP21

CH-1

SW1000 SW1001
MIC 2 GAIN RX

LV3 S2002
PROMPT TX

E13 TP22 CN7 CN8
PROMPT RF RX

NORM MIN MAX

CH-2

S1001
PANEL SELECT
REMOTE LOCAL

S1004
RS232C-2

S1000

PANEL

IF BOARD

TP1001 LV2 TP2001

CONTROL MODE
NORMAL SLAVE

NORM CONT MODE

E16 TP2003 TP2002 TP2004 TP2005 TP23

S1002

SLAVE

CT-181 Board (A SIDE)

� S1000 This switch is for the adjustment in the factory. Factory setting : All OFF � S1001 (PANEL REMOTE/LOCAL) When the RCP or COU is connected, the connected one is selected in spite of PANEL setting. Also, when both RCP and COU are connected, RCP or COU is selected according to the PANEL (REMOTE/ LOCAL) setting. Factory setting : REMOTE Note : RCP : Remote Control Panel RCP-TX7 COU : Camera Operation Unit COU-TX7 � S1002 (CONTROL MODE NORMAL/SLAVE) The RCP is only connected or both RCP and COU are connected and then the S1001 switch is set to REMOTE side. In this case, the RCP is valid, and this S1002 switch is invalid. The COU is only connected or both RCP and COU one connected, and then the S1001 switch is set to LOCAL side. In this case, the COU is valid, and this S1002 switch is used as follows ; NORMAL : COU can be used SLAVE : The operation of CCU can be used. COU can not be used. Factory setting : NORMAL � S1004 This switch is used to change the RS-232C and IF BOARD. Factory setting : RS-232C side

� SW1000 (MIC GAIN � CH1) � SW1001 (MIC GAIN � CH2) Use these screws to adjust the microphone amplifier gain for the camera adaptor. The standard level (NORM) is 0 dB, and the gain setting can be adjusted to any of 16 levels from -12 dB (MIX) to +12 dB.

CCU-TX7 (E)/V1

2-7

You might also want to buy

$4.99

SX-K700 TECHNICS
Owner's Manual

Complete owner's manual in digital format. The manual will be available for download as PDF file aft…

$4.99

CJ-V51 PIONEER
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…

$4.99

GRAND PRIX ELECTRONIC 754 BECKER
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…

$4.99

SX-PR602 TECHNICS
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…

$4.99

EV-S1000E SONY
Owner's Manual

Complete owner's manual in digital format. The manual will be available for download as PDF file aft…

$4.99

GRAND PRIX ELECTRONIC 780 BECKER
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…

$4.99

AG7330 PANASONIC
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…

$4.99

EVO-9850 VOLUME 1 SONY
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…
>
Parse Time: 0.423 - Number of Queries: 130 - Query Time: 0.152